LINEAR LABORATORY POWER SUPPLY
CONSTANT VOLTAGE/CONSTANT CURRENT SUPPLIES
0-400V/0-20
A
HWD SERIES

 

 

APPLICATION:

The HWD Series linear power supplies are designed to be used on the lab bench of for a system application. The HWD Series provides full rated voltage or current at any setting, without the need of derating. The availability of RS485 and RS232 programming options makes the HWD Series a versatile systems test instrument. Digital Voltmeter and ammeter provide accurate readings for the output voltage and current without the need of external DVMs


FEATURES:

  • Digital ammeter/voltmeter
  • Remotely programmable
  • Remote sensing
  • Series and parallel operation
  • 1 mv ripple
  • 10-Turn Voltage Control
  • 10-Turn Current Control
  • RS485-RS232 Control Options

MODEL SELECTION

MODEL NUMBER
OUTPUT
REGULATION
VOLTS
AMPS
LINE%
LOAD%
CV
CC
CV
CC
HWD 6-20B
0-6
0-20
0.01
0.1
0.01 or 1mv
0.5
HWD 10-15B
0-10
0-15
0.01
0.1
0.01 or 1mv
0.5
HWD 20-10B
0-20
0-10
0.01
0.1
0.01 or 1mv
0.5
HWD 50-B
0-50
0-4
0.01
0.1
0.01 or 1mv
0.5
HWD 40-5B
0-40
0-5
0.01
0.1
0.01 or 1mv
0.5
HWD 60-3B
0-60
0-3
0.01
0.1
0.01 or 1mv
0.5
HWD 100-2B
0-100
0-2
0.01
0.1
0.01 or 1mv
0.5
HWD 200-1B
0-200
0-1
0.01
0.1
0.01 or 1mv
0.5
HWD 400-0.5B
0-400
0.5
0.01
0.1
0.01 or 1mv
0.5


     

SPECIFICATIONS

Input:
105-125 Volts AC 50 to 60Hz single phase.
Output: See specific model in table
The output is floating and either side may be grounded.
Load Regulation: See table. Regulation is for a full load step.
Line Regulation: See table. Regulation is for a line change from 105 to 125 or 125 to 105 VAC.
Ripple: Less than 1mv RMS
Response Time: The output voltage is within regulation limits in less than 100 ms for 1/2 load step.
The output voltage will remain within regulation limits for line step from 105 to 125 to 105VAC.
Remote Sensing: To allow for point of load regulation all units are provided with remote sense terminals at the rear.
Remote Programming: All units are voltage programmable at approximately 1000 ohms/volt except Model HWD400-0.5B which is programmable at 400 ohms/volt.
Series/Parallel Operation: Two or more units may be operated in series. Two units of the same voltage and current may be operated in parallel.
Temp. Coef.: 0.02%/degree C.
Stability: Better than 0.05%/8 hours at constant line, load and temperature, after 1/2 hour warm up.
Operation Temperature: 0C to +50C at any combination of line, load and temperature including continuous operation at 125VAC and full load without the need for external cooling.
Terminations: Barrier strip terminals are provided at the rear for output, sensing, remote programming and ground.
5 way binding posts are provided on the front panel for output and ground.
A seven foot 3 detachable wire line cord for AC input.

Protection: The power supply is protected by a fuse in the input line.
The output of the supply is protected by means of the fully adjustable solid state current limiting feature.
Panel Controls: Digital Voltmeter, ammeter, 10 turn voltage control, 10 turn current control, pilot light and on/off switch. Five way binding posts.
The voltage level is fully adjustable by means of a 10 turn panel voltage adjust potentiometer.
Finish: The standard front panel and chassis finish is light blue. Cover is dark blue.
Size: 4-1/2" high x 8" wide x 14" deep. Two units can mount in a 19" wide x 5-1/4" panel. See option 10 and 11 below.

OPTIONS

-06
Addition of an adjustable over-voltage crow bar.
-10 One HWD mounted in 5-1/4 x 19" rack mount tray.
-11 Two HWD mounted in 5-1/4 x 19" rack mount tray.
-27 Chassis Slides (Available with options 10 and 11 only).
-36 Voltage/voltage programming (0-10v= full rated output).
-52 Voltage programming of the output current level (0-10V=0 to full rated current).
-62 3-1/2 digit digital meters.
-85 Voltage/voltage programming (isolated input).
-90 Voltage Programming of the output current level (isolated input).
-108 RS232 control with read back.
-109 IEEE-488.2 control with read back.
-110 RS-485 control with read back
-123 Ethernet option with