int_nav.gif
 
 
 
 
 
 

Other Products:
     
     
 
 

HIGH VOLTAGE SCR
KV SERIES - HIGH VOLTAGE LINEAR POWER SUPPLIES

 

 

APPLICATION:

The KV Series of Power Supplies are constant voltage/constant current units with automatic crossover. Models are available with up to 3 ampere current capacity over the full voltage range. Options such as remote voltage programming, remote current programming and remote turn on and turn off make the unit a versatile piece of equipment for laboratory or manufacturing operations.

FEATURES:

  • Output 0 to 1500 VDC
  • Voltage regulated 0.5%
  • Current regulated 0.5%
  • Voltmeter and ammeter
  • Ripple 0.5% RMS
  • Voltage/voltage programmable
  • Resistance programmable
  • RIEEE488 Programmable

Click here for specs (PDF)

   

MODELS:

  Output Regulation %  
Model Number
KV 1000-0.5
KV 1000-1
KV 1000-2
KV 1000-3
KV 1500-0.5
KV 1500-1
KV 1500-1.5
Voltage Amps
0-1000 0-0.5
0-1000 0-1.0
0-1000 0-2.0
0-1000 0-3.0
0-1500 0-0.5
0-1500 0-1.0
0-1500 0-1.5
Voltage Amps
0.5 0.5
0.5 0.5
0.5 0.5
0.5 0.5
0.5 0.5
0.5 0.5
0.5 0.5
Panel Height
5-1/4
7
10-1/2
14
7
10-1/2
14
     

SPECIFICATIONS

Input:
100 VAC to 130 VAC, 50/60 Hz. Single Phase for Models KV1000 - 0.5 KV1000-1 and KV1500-0.5.

Output:
Adjustable 0 to Rated Voltage in Voltage Mode.
Adjustable 0 to Rated Current in Current Mode.

Regulation:
Voltage: Less than 0.5% for a full load step.
Current: Less than 0.5% for full voltage compliance over the operating range of 100 to 1000 volts.

Ripple: Less than 0.5% for a full load step.

Load Response: Less than 500 milliseconds, for a half load step, to return to regulation limits..

Controls:

  • 10-Turn Voltage Control
  • 10-Turn Current Control
  • Voltmeter
  • Ammeter
  • Input Fuse - KV1000-0.5, KV1000-1 and KV1500-0.5
  • Cicuit breaker-all others

Size:

- KV1000-0.5: 5-1/4" Panel x 19 x 16-1/2 Deep.
- KV1000-1, KV1500-0.5: 7" Panel x 19 x 16-1/2 Deep.
- KV1000-3, KV1500-1.5: 14" Panel x 19 x 16-1/2 Deep.

Termination:

- Input: 5 1/4" and 7" models have 3-wire line cords. All others have a Barrier Terminal Strip.

- Output: Barrier Terminal Strip at the rear.

Operating Ambient: 0 to 50°C without derating.

OPTIONS

-06 Over voltage Protection.

-36 Remote voltage programming (NonIsolated).

-52 Remote current programming (NonIsolated).

-60 Remote Control of DC Output - Turn On/Off.

-85 Isolated Remote Voltage Programming.

-90 Isolated Remote Current Programming.

-110 RS-485 Programming & Read back; V and I.

-112 IEEE488 Programming & Read; V and I.

 

 
 