SPECIFICATIONS
Input: 105-132 VAC. 57-63 Hz. Single phase - applies to 3 1/2", 5 1/4", 8 3/4" and 12 1/4" units. 230 VAC ± 10%, 57-63 Hz. 3 phase - applies to 17 1/2", 24", 48 5/8" and 67 7/8 units.
Other input voltages such 208, 440, etc., available on special order. No additional charge on quality orders.
Output: Floating; either side may be grounded. Output voltage variable over approximately ± 10% range.
Regulation: ± 1% total bandwidht; including ± 10% line changes and full load changes.
Ripple: 1/2% RMS of output voltage
Remote Programming: All units are voltage programmable at approximately 1000 /Volt.
Series/Parallel Operation: Two or more units may be operated in series. Two units of the same voltage and current may be operated in parallel.
Temp. Coef.: 0.02%/ degree C.
Stability: Better than 0.05% / 8 hours at constant line, load and temperature, after 1/2 hour warm up.
Operation Temperature: 0C to +60C at any combination of line, load and temperature including continuous operation at 125 VAC and full load without the need for external cooling.
Terminations: Barrier strip terminals are provided at the rear for AC input, output, sensing, remote programming, slaving and ground.
|
Protection: All units completely protected against damage due to short circuits by solid state overload circuits.
Control: Screwdriver ajustment at rear.
Termination: At rear; input, output, sensing and ground connections on screw barrier strip.
Temperature: Continous operation in ambients up 60C grades.
System Choices: Special panel finished to mach your system will be furnished at no aditional cost on cuantity orders. Other choises are special connectors. 24" wide panel meters, Mil specs, handles, switches, pilots, etc., all of which can be readily incorporated at very little extra cost on cuantity orders.
Construction: The 48 5/8" and 67 7/8" units are rack cabinets 22" wide by 22" deep. All other sizes are standard 19" wide panels with chassis extending 16 1/2" behind the panel.
|